+91-8553071317

You have no items in your shopping cart.

Harayana

Maharastra

Telangana

Andhra Pradesh

Karnataka

Pre-approved subsidy ~30%

Available for solar systems to be installed on roofs of below categories of customers:

Residential

All types of buildings

Applicable states

Institutions
  • Educational Institutions
    • Schools
    • Universities
  • Health Institutions
    • Hospitals
    • Medical College
Type of System :

Grid-connected solar systems (without batteries)

System Sizes :

5kW, 10kW, 15kW, 20kW, 25kW

Features :

Included (remote Monitoring System + O & M for 5years

Payback

31/2 years to 41/2

Return on Investment

20% to 25%

Contact us

+91-8553071317

leave details below

6KW GRID-TIED SOLAR SYSTEM WITH 9 UNITS BATTERY BACK-UP STUDER 2.6KW HYBRID INVERTERS

Items Included Qty
SOLAR PANEL 250WP (PREMIUM GRADE) 28
STUDER XTENDER XTM 2600-48 SINGLE PHASE HYBRID INVERTER (EUROPEAN GRADE) 3
SOLAR TUBULAR BATTERIES, 200AH 4
NAVSEMI MPPT CC IMAX 1000V/48 4
FLAT ROOF MOUNTING STRUCTURE SET (MS WITH PAINT) 1
DC SOLAR CABLES (UV PROTECTED , OUTDOOR RATED, LONG LIFE) - 1 SET (PREMIUM GRADE) 1
AC CABLES (COPPER) & ACCESSORIES - 1 SET (PREMIUM GRADE) 1
EARTHING KIT SET 1
DATA LOGGER 1

7KW GRID-TIED SOLAR SYSTEM WITH 9 UNITS BATTERY BACK-UP STUDER 2.6KW HYBRID INVERTERS

  • 24X7 back-up through solar
  • 840 units/mth solar power
  • Excess solar power exported to grid
  • 7000W solar panels
  • 3 X 2.6KW hybrid inverters
  • Financing starting @ 10.75% p.a.
Offsets 9.8 tonnes of CO2/yr
Elec. bill savings: 10080 units/yr

Enter Pincode to check Price / Delivery for your location

Why buy on glowship

Sold by : GCT Solutions

Kit Specifications

Applications
  • Provides 24X7 back-up through solar power
  • Operating Principle:

Scenario

Usage Pattern

During Day hours + Power ON

If Solar > Loads

  • Solar powers Loads
  • Excess Solar charges Battery (if required)
  • Balance Solar exported to Grid

If Solar < Loads

  • Solar powers Loads
  • Balance fed by Grid / Balance fed by Battery (configurable based on whether grid export is profitable or not)

During Day hours + Power CUT

If Solar > Loads

  • Solar powers Loads
  • Excess Solar charges Battery (if required)
  • Solar production limited to requirement of Loads + Battery

If Solar < Loads

  • Solar powers only Secured Loads*
  • Balance Secured Loads fed by Battery

During Night hours + Power CUT

  • Secured Loads fed by Battery

During Night hours + Power ON

  • Loads fed by Battery (till Battery reaches reserve) / Grid
  • Grid charges Battery (if required)

*Secured loads: Applicable if separate wiring is done for  Emergency loads

  • Reduces electricity bill & provides valuable back-up to loads through solar power
Solar Capacity Provided (Wp) 7000
Avg. Energy from Solar (estd.) 840 units/month
Approx. Area Required 700sqft
Approved for Net Metering Karnataka
Solar Panel (Wp) 28nos, 250Wp
Solar Panel Brand Emmvee/Shaan or equivalent
Inverter Type Hybrid
Solar Inverter Brand Studer
Model No./Qty XTM-2600-48 /3 nos
System Phase Three Phase
Charge Controller NavSemi, MPPT Type
Battery 200AH (C10 capacity), Solar Tubular Battery, 4 nos.
Data Logger Studer, RCC-02
Panel Mounting Structure Flat roof type, MS with paint
Est. Carbon savings Offsets 9.8 tonnes of CO2/yr
Est. Electricity savings Elec. bill savings: 10080 units/yr

Net Metering & Booking Process

Procedure Under Net Metering Scheme (Karnataka) Grid tie flow chart
Booking Process Booking Process Flow Chart
Fees & Charges
  • Payable to ESCOM:

S.No.

Capacity of Solar System

Registration Fees

Facilitation Fees

1

Upto & inclusive of 5 KWp

Rs 500/-

Rs 1000/-

2

Above 5KWp & upto 50 KWp

Rs 1000/-

Rs 2000/-

 

  • Indicative cost of Bi-Directional meter & Testing charges

S.No.

Capacity

Class of Accuracy

Description of Type of Bi-dircetional meter

Estd. Price

Testing Charges

1

Upto 5KW

1.0

S-Phase, 2 Wire

Rs 2,900/-

Rs 200/-

2

Above 5KW to 17.5KW

1.0

3-Phase, 4 Wire, Whole current

Rs 7,000/-

Rs 1800/-

Commissioning Requirements
  • Post installation of the solar system
    • Work Completion Report (Format 7) along with necessary enclosures
    • Copy of Power Purchase Agreement with ESCOM on Rs.200/- stamp paper

Financing

Loan Financing Details

 

 Residential Customers

Interest Rate

 Starting @ 10.75% pa

Loan Amount

 Upto 85% of project value

Min / Max

 INR 0.5 Lac / 25 Lac

Payment

 EMI

Tenure

 3 - 5 years

Collateral

 Primary: Solar Equipment

 Secondary: Collateral determined upon credit score. 

 In general,

  • Upto 1 lac, no collateral
  • Upto 3 lac, no collateral for high credit customers
  • Beyond 3 lacs: Personal guarantee letter, FD, LIC Policy etc.

Processing Fees

 0.5% of loan amount

Time to Loan

 2 – 3 weeks

Documents Required

 ID Proof:

  • One of (Passport/Voter ID, Driving License, Aadhar Card) 

 Address Proof:

  • One of (Passport/Voter ID, Driving License, Aadhar Card, Recent 2 months Utility bill)

 Salary Proof:

  • Bank statement (last 6 months)
  • Salary slip (last 3 months)
  • IT returns (last 3yrs) 

 Copy of Utility Bill

 2 passport size photographs

Savings & Benefits

Benefits against Conventional UPS System
  • Reduced consumption of grid power: Solar power consumed offsets an equivalent # of units of grid power
  • Additional earnings under net-metering scheme: Surplus solar power injected into the grid (on a monthly basis), earns Rs 9.56/unit (in Karnataka)
Estimated Runtime
  • Back-up duration available through energy stored in the battery 

LCD TV (42")

Ceiling Fans

Tubelights

CFL lights

Personal Computer

Split AC - 0.75 ton

Split AC - 1.5 ton

Refrigerator - 300 ltrs

Total Load (W)

Back-up time (hrs)

1

5

5

10

0

1

0

1

1920

3.20

3

5

5

10

1

1

0

2

2880

2.13

3

5

5

10

1

0

1

1

3840

1.60

3

5

5

10

1

1

1

2

4800

1.28

It is advisable to turn High Power appliances like Refrigeartors, Air Conditioners, Water Pumps etc. ON one after the other. It is also advisable to run these appliances on back-up power only for a short duration

Technical Specifications

Inverter Input Specifications (DC)

Input Voltage Range

 150 to 265Vac

Input Frequency

 45 to 65Hz

Input Current Max. (transfer relay) / Output Current Max. 

 50Aac/56Aac

Nominal Battery Voltage

 48V

Inverter Output Specifications (AC)

Continuous power @ 25 deg C

 2000VA

Power 30min. @ 25 deg C

 2600VA

Power 5 sec. @ 25 deg C

 6.5 kVA

Max. Efficiency

 96%

Harmonics

 <2%

Inverter Features
  • True sine wave voltage
  • Reliable and silent with any kind of load
  • Outstanding overload capabilities
  • Smart-Boost function for assistance to the source even with difficult loads
  • Automatic reduction of peak loads (power shaving)
  • Multi-stage programmable battery charger with PFC
  • Stand-by level adjustable over a large range and from a very low threshold
  • Ultra-fast transfer relay
  • Control by digital signal processors (DSP)
  • High efficiency
Inverter Detailed Specifications Brochure
Charge Controller Specifications

Panel Rating

Output

Voc Max (V)

Vmpp Range

Isc (A)

Max. Panel Power (Wp)

Battery Voltage (V)

Max. Battery Current (A)

150

75-105

10

1200

48

20

Warranty & Certifications

Complete System Warranty 1 yr against manufacturing defects
Solar Panel Warranty 5 yrs
Solar Panel Performance Warranty 90% upto 10 years and 80% upto 25 years
Inverter Warranty 5 yrs
Battery warranty 3 years
Solar Panel Certifications IEC 61215 (Design & Performance), IEC 61730 (Safety Class II)
Inverter Certifications/Standards
  • Directive EMC 2004/108/EC : EN 61000-6-1, EN 61000-6-3, EN 55014, EN 55022, EN 61000-3-2, 62040-2 Low voltage directive 2006/95/EC : EN 62040-1-1, EN 50091-2, EN 60950-1

In the Box

In the box
  • Solar panels (Premium) 250Wp : 28 nos
  • Studer Xtender (XTM 2600-48) Three Phase Hybrid Inverter - 3 Nos.
  • Solar Tubular Batteries: 200AH, 4 nos.
  • MPPT Charge Controller: NavSemi, IMAX 1000V/48 - 4 Nos.
  • Flat roof mounting structure (MS with Paint) - 1 set 
  • DC solar cables (UV Protected (Premium), Outdoor rated, Long Life): Upto 90m.
  • AC cables (Copper) - Polycab, Lapp or equivalent - 1 set (As required)
  • Switches, Fuses, Breakers: 1 set (As required)
  • Earthing Kit: 1 set
  • Data Logger: 1 set
Installation Requirements
  • Solar panels to be placed in an area that is shadow-free at least between 9am-3pm for optimum performance
  • Solar panels are to be installed preferably in south facing direction at an inclination that equals the latitude of the location
  • Min. 7 KVA Sanctioned load capacity for your premises 

Reviews

Write a product review

Only registered users can write reviews. Please log in or register